General manufacturers only measure the temperature of bearing outside diameter, which is unscientific. As shown below, bearing surface temperature is only 40°C, while the bearing internal and grease temperature has reached 130°C. YBN has taken the lead to treat bearing inside maximum temperature as a measure of the temperature indicator. When the environment temperature is 25°C, the rotating speed is 18000RPM, YBN bearing and a well-known brand bearing run for two hours under the same axial load of 100N, we compared the bearing highest temperature measured by the thermal infrared imager.
Experiment Condition |
Bearing Item |
Highest temperature |
Average temperature |
||
YBN bearing |
A well-known brand bearing |
YBN bearing |
A well-known brand bearing |
||
When the environment temperature is 25°C, the rotating speed is 18000RPM, bearings run for two hours under the same axial load of 100N, we compared the bearing highest tem- perature measured by the thermal infrared imager. Effective measuring distance is 5M. |
608 |
42.26 °C |
61.41 °C |
31.59 °C |
39.89 °C |
6201 |
77.24 °C |
132.87°C |
54.76 °C |
76.10 °C |
|
629 |
53.69 °C |
109.71°C |
32.20 °C |
53.69 °C |
|
6002 |
42.41 °C |
100.18°C |
26.60°C |
50.13 °C |
Contact: Doris Zhang
Phone: 0086 15021127104
Tel: 0086-021-62168006
Email: info@ybnbearing.com
Add: Room2515, Building 2, No. 28, Jiafeng Road, Shanghai Free Trade Zone